TCRT October 2009

category image Volume 8
No. 5 (p. 315-400)
October 2009
ISSN 1533-0338

Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy (369-378)

Objectives. The goal of this study was to dosimetrically compare 3-dimensional radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (TOMO) plans for whole abdominopelvic radiotherapy (WART) in patients with gynecologic cancer.
Methods. Ten patients were selected for WART planning. Doses were prescribed to planning target volumes (PTVs) as the followings: 30 Gy to PTV-whole abdominopelvis (PTV-WA), 40 Gy to PTV-para-aortic lymph node (PTV-PALN), 44 Gy to PTV-pelvis, and 50 Gy to gross target volume (GTV) in 20 fractions. Dose to whole liver, both kidneys, and spinal cord were constrained below each tissue tolerance, and bone marrow (BM)-sparing technique was adopted in IMRT and TOMO. Dosimetric parameters and treatment times were compared among plans.
Results. Calculated doses in TOMO came most closely to the prescribed dose for coverage of PTV-WA, PTV-PALN, PTV-pelvis, and GTV compared to 3DCRT, and IMRT. In normal organs, TOMO had significantly better dosimetric profiles compared to IMRT and 3DCRT. TOMO significantly reduced V20Gy, and mean dose of whole liver, both kidneys, and spinal cord. The use of BM-sparing technique (BMS) did not impair coverage of target volume in IMRT and TOMO. While IMRT showed no differences of irradiated BM dose using BMS, TOMO with BMS reduced half V20Gy of BM compared to TOMO without BMS. Conclusions. TOMO showed dosimetric superiority in target coverage, sparing BM, and other normal organs compared to 3DCRT and IMRT. Clinical experiences will be needed for evaluation of feasibility of WART using TOMO in patients with gynecologic cancer.

Yong Bae Kim, M.D.
Joo Ho Kim, C.M.D.
Kyung Keun Jeong, Ph.D.
Jinsil Seong, M.D.
Chang Ok Suh, M.D.
Gwi Eon Kim, M.D.*

Department of Radiation Oncology Yonsei Cancer Center, Brain Korea 21 Project for Medical Sciences Yonsei University College of Medicine, Seoul, Korea

gekim@yuhs.ac

Purchase Downloadable Full-text PDF of Articles

Corporate User

$100.00

University/Academic User

$50.00

Subscription is more cost effective than purchasing PDFs on-the-fly.  Click here for details.

Member Login | Home | Editorial Board | Instructions | Subscribe | Contact Us

Adenine Press, 2066 Central Avenue, Schenectady, NY 12304 USA
phone: 518-456-0784; fax: 518-452-4955; email: info@adeninepress.com
copyright © Adeninepress, All rights reserved.