TCRT April 2009

category image Volume 8
No. 2 (p 85-176)
April 2009
ISSN 1533-0338
Megavolted Computed Tomotherapy (MVCT)

Megavoltage Computed Tomography Image-based Low-dose Rate Intracavitary Brachytherapy Planning for Cervical Carcinoma (p. 123-130)

Initial results of megavoltage computed tomography (MVCT) brachytherapy treatment planning are presented, using a commercially available helical tomotherapy treatment unit and standard low dose rate (LDR) brachytherapy applicators used for treatment of cervical carcinoma. The accuracy of MVCT imaging techniques, and dosimetric accuracy of the CT based plans were tested with in-house and commercially-available phantoms. Three dimensional (3D) dose distributions were computed and compared to the two dimensional (2D) dosimetry results. Minimal doses received by the 2 cm3 of bladder and rectum receiving the highest doses (DB2cc and DR2cc, respectively) were computed from dose-volume histograms and compared to the doses computed for the standard ICRU bladder and rectal reference dose points. Phantom test objects in MVCT image sets were localized with sub-millimetric accuracy, and the accuracy of the MVCT-based dose calculation was verified. Fifteen brachytherapy insertions were also analyzed. The ICRU rectal point dose did not differ significantly from DR2cc (p=0.749, mean difference was 24 cGy ± 283 cGy). The ICRU bladder point dose was significantly lower than the DB2cc (p=0.024, mean difference was 291 cGy ± 444 cGy). The median volumes of bladder and rectum receiving at least the corresponding ICRU reference point dose were 6.1 cm3 and 2.0 cm3, respectively. Our initial experience in using MVCT imaging for clinical LDR gynecological brachytherapy indicates that the MVCT images are of sufficient quality for use in 3D, MVCT-based dose planning.

Key words: Intracavitary brachytherapy; Megavoltage computed tomography; MVCT; Tomotherapy; Cervical carcinoma.

Thomas H. Wagner, Ph.D.*
Katja M. Langen, Ph.D.
Sanford L. Meeks, Ph.D.
Twyla R. Willoughby, MS
Omar A. Zeidan, Ph.D.
Robert J. Staton, Ph.D.
Amish P. Shah, Ph.D.
Rafael R. Manon, MD
Patrick A. Kupelian, MD

Department of Radiation Physics
M. D. Anderson Cancer Center Orlando
1400 S. Orange Avenue, MP 730
Orlando, FL 32828, USA

*Thomas.wagner@orlandohealth.com

Purchase Downloadable Full-text PDF of Articles

Corporate User

$100.00

University/Academic User

$50.00

Subscription is more cost effective than purchasing PDFs on-the-fly.  Click here for details.

Member Login | Home | Editorial Board | Instructions | Subscribe | Contact Us

Adenine Press, 2066 Central Avenue, Schenectady, NY 12304 USA
phone: 518-456-0784; fax: 518-452-4955; email: info@adeninepress.com
copyright © Adeninepress, All rights reserved.


Mountain Media ecommerce solutions Ecommerce Solutions by Mountain Media