TCRT April 2007

category image Volume 6
No. 2 (p 57-150)
April 2007
ISSN 1533-0338
Intensity Modulated Radiotherapy

Comparison of Contralateral Breast Dose for Various Tangential Field Techniques in Clinical Radiotherapy (p. 135-138)

Contralateral breast (CLB) cancer is a rare but serious concern in radiotherapy. In this study, the CLB dose was measured using MOSFET dosimeter in 49 patients who underwent breast conservation surgery treated by different radiotherapy tangential field techniques, which included enhanced dynamic wedge (EDW), physical wedge, and intensity modulated radiation therapy (IMRT). The mean percent of the prescribed dose received by the contralateral areola in treatment technique using physical wedge (Cobalt), physical wedge (Linac), EDW, and IMRT were 4.27% (SD: 0.65), 3.61% (SD: 0.60), 3.38% (SD: 0.58), and 1.65% (SD: 0.24), respectively. There was a 29% CLB dose reduction at 3 cm from the medial tangential field border with IMRT compared to other wedged tangential field techniques. The study shows that the CLB dose could be reduced with IMRT or reducing or avoiding the medial wedge in conventional tangential field planning for breast cancer.

Keywords: Contralateral breast dose; Tangential fields; and IMRT.

R. Prabhakar, Ph.D.1,*
P. K. Julka, M.D.1
M. Malik, M.D.1
T. Ganesh, Ph.D.1
R. C. Joshi, Ph.D.1
P. S. Sridhar, M.D.1
G. K. Rath, M.D.1
G. S. Pant, Ph.D.3
S. Thulkar, M.D.2

1Department of Radiation Oncology
Institute Rotary Cancer Hospital
All India Institute of Medical Sciences
New Delhi ?110 029, India
2Department of Radiology
All India Institute of Medical Sciences
New Delhi ?110 029, India
3Department of Nuclear Medicine
All India Institute of Medical Sciences
New Delhi ?110 029, India
*prabhakar_smr@hotmail.com

Purchase Downloadable Full-text PDF of Articles

Corporate User

$100.00

University/Academic User

$50.00

Subscription is more cost effective than purchasing PDFs on-the-fly.  Click here for details.

Member Login | Home | Editorial Board | Instructions | Subscribe | Contact Us

Adenine Press, 2066 Central Avenue, Schenectady, NY 12304 USA
phone: 518-456-0784; fax: 518-452-4955; email: info@adeninepress.com