Development and Monte Carlo Analysis of Antiscatter Grids for Mammography (p. 441-448)

Mammography arguably demands the highest fidelity of all x-ray imaging applications, with simultaneous requirements of exceedingly high spatial and contrast resolution. Continuing technical improvements of screen-film and digital mammography systems have led to substantial improvements in image quality, and therefore improvements in the performance of anti-scatter grids are required to keep pace with the improvements in other components of the imaging chain. The development of an air-core honeycomb (cellular) grid using x-ray lithography and electroforming techniques is described, and the production of a 60 mm × 60 mm section of grid is reported. A crossed grid was constructed with 25 μm copper septa, and a period of 550 μm. Monte Carlo and numerical simulation methods were used to analyze the theoretical performance of the fabricated grid, and comparisons with other grid systems (Lorad HTC and carbon fiber interspaced grids) were made over a range of grid ratios. The results demonstrate essentially equivalent performance in terms of contrast improvement factor (CIF) and Bucky factor (BF) between Cu and Au honeycomb grids and the Lorad HTC (itself a copper honeycomb grid). Gold septa improved both CIF and BF performance in higher kVp, higher scatter geometries. The selectivity of honeycomb grids was far better than for linear grids, with a factor of ~3.9 improvement at a grid ratio of 5.0. It is concluded that using the fabrication methods described, that practical honeycomb grid structures could be produced for use in mammographic imaging, and that a substantial improvement in scatter rejection would be achieved using these devices.

John M. Boone, Ph.D.1,*
Olga V. Makarova, Ph.D.2
Vladislav N. Zyryanov, Ph.D.2
Cha-Mei Tang, Sc.D.2
Derrick C. Mancini, Ph.D.3
Nikolaie Moldovan, Ph.D.3
Ralu Divan, Ph.D.3

1Department of Radiology
U. C. Davis Medical Center
Research Imaging Center
4701 X Street
Sacramento, CA 95817, USA
2Creatv MicroTech, Inc.
Rockville, Maryland, USA
3Argonne National Laboratory Argonne
Illinois 60439, USA
*jmboone@ucdavis.edu

Purchase Downloadable Full-text PDF of Articles

Corporate User

$100.00

University/Academic User

$50.00

Subscription is more cost effective than purchasing PDFs on-the-fly.  Click here for details.

Member Login | Home | Editorial Board | Instructions | Subscribe | Contact Us

Adenine Press, 2066 Central Avenue, Schenectady, NY 12304 USA
phone: 518-456-0784; fax: 518-452-4955; email: info@adeninepress.com
copyright © Adeninepress, All rights reserved.